سال انتشار: ۱۳۸۴

محل انتشار: سمپوزیوم برآورد عدم قطعیت در مهندسی سد

تعداد صفحات: ۹

نویسنده(ها):

H. R. VOSOUGHIFAR – Civil Engineering Department, Islamic Azad University, Tehran South Unit, Tehran, Iran
A. SHAMSAI – Civil Engineering Department, Sharif University of Technology, Tehran, Iran

چکیده:

Rolled compacted concrete (RCC) dams are similar to soil dams regarding to cost and similar to concrete dams based on safety condition. Therefore the designs are based on suitable mix design are considered for enough permeability coefficient, low cost, probability of separation, more strength and safety. In this paper a try have been made to look at permeability as an entrance problem. Then the suitable mix design is provided based on three control factors including: strength of concrete samples, project total cost and separation during transportation, pure, spread and compaction. The meaning of suitable mix design is to use minimum amount of cement per cubic meter and maximum amount of pozzolans to cement ratio. With considering to the results in this paper in Iran, which are in the high risk of earthquake hazard, for an economic project, the use of Fly ash pozzolans with low lime and natural pozzolans with comparisons to the other pozzolans are suitable. To reach to the maximum drydensity for suitable permeability, it is require to: 6.5% moisture, 40% to 50% of water per cement ratio and 20% to 25% fine aggregate. These will cause to reduce the cement quantities to 75 to 90 Kg and pozzolans from 100 to 120 Kg per cubic meter.